1. The controller displays ALARM after turning on the power
1. The manual method to unlock the controller: Turning the key switch on, then the unlock light of the controller is on, let the loading technician proceed the demagnetization operations (loading/unloading the mold)
2 When the injection molding machine displays an emergency stop, pump overload and the red lights of both the fixed and moved platens flashing, the method to clear the alert is as follows: Pressing the keys of fixed platen and moved platen simultaneously for 3 seconds, then the controller displays “OP”, and pressing “alert cancelled” on the computer panel of injection molding machine.
2. Start loading the mold
1. Lifting the mold first, positioning the alignment hole on the fixed platen, starting the pump and adjusting the mold thickness, and finally locking the mold.
2. Magnetizing the fixed platen (press the three keys of “unlock”+ “fixed platen”+ the <green> "Magnetize" simultaneously for two seconds). As the Magnetization completes, the green “MAC” indicator light on the controller of fixed platen is on, and meantime the green indicator light on the fixed magnetizing platen is also on.
3. Magnetizing the moved platen (press the three keys of “unlock”+ “moved platen”+ the <green> "Magnetize" simultaneously for two seconds). As the Magnetization completes, the green “MAC” indicator light on the controller of moved platen is on, and meantime the green indicator light on the moved magnetizing platen is also on.
4. As the Magnetization completes, locking the controller, turning the key switch off, the unlock light of the controller going out to avoid the misoperation by the non-operators.
5. After the operation of loading mold completes, releasing the crane hook, starting the pump motor, opening the mold and being ready to produce
4. Unloading mold
1. Using the crane hook to hook up the mold, manually pressing the key to unlock the controller (turning the key switch on and the unlock light of controller on)
2. Demagnetizing the fixed platen (press the three keys of “unlock”+ “fixed platen”+ the <yellow> "Demagnetize" simultaneously for two seconds). As the demagnetization completes, the yellow “DEMAC” indicator light on the controller of fixed platen is on, and meantime the green indicator light on the fixed magnetizing platen is off.
3. Pressing the “Function key” to reset. As displaying P status, the moved platen is demagnetized (press the three keys of “unlock”+ “moved platen”+ the <yellow> "Demagnetize" simultaneously for two seconds). After the demagnetization completes, the yellow “DEMAC” indicator light on the controller of moved platen is on, and meantime the green indicator light on the moved magnetizing platen is off. (All the operations of demagnetization mentioned above should be proceeded as the controller displaying “P” status. Otherwise, it is required to press the “Reset” key on the controller)
4. When the injection molding machine displays a alert of emergency stop or pump overload, the alert can be cleared as follows: (Pressing the keys of fixed platen and moved platen simultaneously for 3 seconds, then the controller displays “OP”, and pressing “alert cancelled” on the computer panel of injection molding machine.), turning on the pump, opening the mold and lifting the mold. 